Last Updated on June 26, 2023
THIS IS A WORK IN PROGRESS
Click here to go to the Combined Config Item Reference Table.
Introduction
This page provides a visual reference for all configurable items within the ProSimB738 Combined Config menu. For corrections, contributions, or enhancement requests, please contact me.
Contents
Forward Overhead (FWD OH)
Forward Overhead
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

APU GEN 1 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU GEN 1 Off*
APU GEN 1 Center
APU GEN 1 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON) OFF (ON)
Center-Locking
Spring-loaded to Center position
AFT CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
AFT CAB selector
Hardware:
10K Potentiometer
ALPHA VANE HEAT L INDICATOR

ALPHA VANE HEAT R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Alpha Vane Heat R*
*The ProSim virtual panel shows the indicator incorrectly as “L ALPHA VANE”. It should be “R ALPHA VANE” as per the real aircraft.
ALT HORN CUTOUT SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Alt horn cutout Off
Alt horn cutout Pushed
Hardware:
Momentary push button, (ON)-OFF
ALTERNATE FLAPS CTRL SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Alternate flaps ctrl Up
Alternate flaps ctrl Off
Alternate flaps ctrl Down*
*=Momentary
Hardware:
Honeywell 1TL1-5
3-POS ON-OFF-(ON)
ALTERNATE FLAPS SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Alternate flaps Off
Alternate flaps Arm
Hardware:
Honeywell 1TL1-2
Guarded 2-POS OFF-ON
In Arm position when guarded
APU FAULT INDICATOR

APU GEN 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU GEN 2 Off*
APU GEN 2 Center
APU GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON) OFF (ON)
Center-Locking
Spring-loaded to Center position
APU GEN OFF BUS INDICATOR

APU LOW OIL PRESSURE INDICATOR

APU MAINT INDICATOR

APU OVERSPEED INDICATOR

APU SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
APU Switch Off
APU Switch On
APU Switch Start*
*=Momentary
Hardware:
Honeywell 1TL1-5K
3-POS ON-OFF-(ON)
Spring-loaded from Start to On
ATTEND SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Attend Off
Attend Pushed
Hardware:
Momentary push-button, (ON)-OFF
AUTO SLAT FAIL INDICATOR

ProSim System: Flight Controls
ProSim Group: Indicator
ProSim Config Names:
Auto slat Fail
AUX PITOT HEAT INDICATOR

BAT DISCHARGE INDICATOR

BATTERY SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Battery switch Off
Battery switch On
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In On position when guarded
BLEED 1 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 1 Off
Bleed 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED 2 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed 2 Off
Bleed 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED APU SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Bleed APU Off
Bleed APU On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
BLEED TRIP OFF 1

BLEED TRIP OFF 2

BUS TRANSFER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Bus transfer switch Off
Bus transfer switch Auto
Hardware:
Honeywell 1TL1-1
Guarded 2-POS ON-OFF
In Auto position when guarded
CABIN TEMP SELECTOR SWITCH

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Air Temp Selector CONT CAB
Air Temp Selector DUCT FWD
Air Temp Selector DUCT AFT
Air Temp Selector CAB FWD
Air Temp Selector CAB AFT
Air Temp Selector R
Air Temp Selector L
Hardware:
8-Position Rotary Switch
CABIN TEMPERATURE GAUGE

CABIN VSI GAUGE

CALL INDICATOR

CAPT PITOT HEAT INDICATOR

CONT CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
CONT CAB selector
Hardware:
10K Potentiometer
COPILOT PITOT HEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Copilot Pitot Heat*
*NOTE: This is the correct item name for the “F/O PITOT” indicator
COWL ANTI-ICE L INDICATOR

COWL ANTI-ICE R INDICATOR

COWL VALVE OPEN L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open L
Cowl valve open L bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
COWL VALVE OPEN R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Cowl valve open R
Cowl valve open R bright (GATE)*
*This is a dual-brightness indicator. The bright state is activated by a gate. Bright indicates the valve is in transit and dim indicates a full open state.
CROSSFEED INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
Crossfeed indicator
Crossfeed indicator bright
This is a dual-brightness indicator
CROSSFEED SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Crossfeed Off
Crossfeed On
Hardware:
Honeywell 7AS12
90 Degree 2-POS Rotary
Knob P/N BP073-109
DISCONNECT 1 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 1 Normal
Disconnect 1 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISCONNECT 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Disconnect 2 Normal
Disconnect 2 Off
Hardware:
Honeywell 1TL1-2
Guarded 2-POS ON-OFF
In Normal position when guarded
DISPLAY CONTROL PANEL SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Display Control Panel Both on 1
Display Control Panel Normal
Display Control Panel Both on 2
DISPLAY SOURCE SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Display source All on 1
Display source Auto
Display source All on 2
Hardware:
8 Position Rotary (restricted to 3 positions)
DOOR AFT CARGO INDICATOR

DOOR AFT ENTRY INDICATOR

DOOR AFT SERVICE INDICATOR

DOOR AIR STAIRS INDICATOR

DOOR EQUIP INDICATOR

DOOR FWD CARGO INDICATOR

DOOR FWD ENTRY INDICATOR

DOOR FWD SERVICE INDICATOR

DOOR LEFT AFT OVERWING INDICATOR

DOOR LEFT FWD OVERWING INDICATOR

DOOR RIGHT AFT OVERWING INDICATOR

DOOR RIGHT FWD OVERWING INDICATOR

DRIVE 1 INDICATOR

DRIVE 2 INDICATOR

DUAL BLEED INDICATOR

ELEC MAINT SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec maint Off
Elec maint Pushed
Hardware:
Momentary push button, (ON)-OFF
ELEC PNL AC SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Elec Pnl AC STBY PWR
Elec Pnl AC GRD PWR
Elec Pnl AC GEN1
Elec Pnl AC APU GEN
Elec Pnl AC GEN2
Elec Pnl AC INV
Elec Pnl AC TEST
Hardware:
8 Position Rotary Switch
(restricted to 7 positions)
ELEC PNL DC SWITCH

ProSim System: Electric
ProSim System: Switch
ProSim Config Names:
Elec Pnl DC STBY PWR
Elec Pnl DC BAT BUS
Elec Pnl DC BAT
Elec Pnl DC AUX BAT
Elec Pnl DC TR1
Elec Pnl DC TR2
Elec Pnl DC TR3
Elec Pnl DC TEST
Hardware:
8 Position Rotary Switch
ELECTRIC PANEL LCD

ELEV PITOT HEAT L INDICATOR

ELEV PITOT HEAT R INDICATOR

EMER EXIT LIGHTS SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Emer Exit Light Off
Emer Exit Lights Armed
Emer Exit Lights On
ON position is the active state when guard is closed.
Hardware:
Honeywell ITL1-1
3-POS ON-OFF-ON
EMERG EXIT LIGHTS NOT ARMED INDICATOR

ProSim System: Lighting
ProSim Group: Indicator
ProSim Config Names:
Emerg Exit Lights not armed
ENG ANTI-ICE 1 SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 1 Off
Eng Anti-Ice 1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG ANTI-ICE 2 SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Eng Anti-Ice 2 Off
Eng Anti-Ice 2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
ENG VALVE CLOSED L INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
ENG Valve Closed L
ENG Valve Closed L bright
This is a dual-brightness indicator
ENG VALVE CLOSED R INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
ENG Valve Closed R
ENG Valve Closed R bright
This is a dual-brightness indicator
EQUIP COOLING EXAUST OFF INDICATOR

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Equip cooling exhaust Off
EQUIP COOLING EXAUST SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling exhaust Normal
Equip cooling exhaust Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
EQUIP COOLING SUPPLY OFF INDICATOR

EQUIP COOLING SUPPLY SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Equip cooling supply Normal
Equip cooling supply Alternate
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
FEEL DIFF PRESS INDICATOR

FILTER BYPASS L INDICATOR

FILTER BYPASS R INDICATOR

FLT ALT DISPLAY

FLT CTRL A SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Flt Ctrl A Stby Rud
Flt Ctrl A Off
Flt Ctrl A A On
Hardware:
Honeywell 1TL1-1
Guarded 3-POS ON-OFF-ON
In A On position when guarded
FLT CTRL B SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Flt Ctrl B Stby Rud
Flt Ctrl B Off
Flt Ctrl B B On
Hardware:
Honeywell 1TL1-1
Guarded 3-POS ON-OFF-ON
In B On position when guarded
FLT CONTROL LOW PRESSURE A INDICATOR

ProSim System: Hydraulic
ProSim Group: Indicator
ProSim Config Names:
FLT Control low pressure A
FLT CONTROL LOW PRESSURE B INDICATOR

ProSim System: Hydraulic
ProSim Group: Indicator
ProSim Config Names:
FLT Control low pressure B
FLIGHT ALT ENCODER

ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Flight alt in encoder
NOTE: other related inputs include:
Flight alt in encoder pulse down Off (SWITCH)
Flight alt in encoder pulse down On (SWITCH)
Flight alt in encoder pulse up Off (SWITCH)
Flight alt in encoder pulse up On (SWITCH)
Flight alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
FMC SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
FMC Normal
FMC Both on L
FMC Both on R
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
FUEL CENTER LEFT LP INDICATOR

FUEL CENTER LEFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Left Off
Fuel Center Left On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL CENTER RIGHT LP INDICATOR

FUEL CENTER RIGHT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Center Right Off
Fuel Center Right On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT AFT LP INDICATOR

FUEL LEFT AFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Aft Off
Fuel Left Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL LEFT FWD LP INDICATOR

FUEL LEFT FWD SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Left Fwd Off
Fuel Left Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Fwd Off
Fuel Right Fwd On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT AFT LP INDICATOR

FUEL RIGHT AFT SWITCH

ProSim System: Fuel
ProSim Group: Switch
ProSim Config Names:
Fuel Right Aft Off
Fuel Right Aft On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
FUEL RIGHT FWD LP INDICATOR

FUEL TEMPERATURE GAUGE

FWD CAB SELECTOR

ProSim System: Pneumatic
ProSim Group: Analog
ProSim Config Names:
FWD CAB selector
Hardware:
10K Potentiometer
GALLEY SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Galley Off
Galley On
Hardware:
Honeywell 1TL12
2-POS ON-OFF
GEN OFF BUS 1 INDICATOR

GEN OFF BUS 2 INDICATOR

GEN 1 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 1 Off*
GEN 1 Center
GEN 1 On*
*=Momentary
Hardware:Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GEN 2 SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
GEN 2 Off*
GEN 2 Center
GEN 2 On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center position
GROUND CALL SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Ground call Off
Ground call Pushed
Hardware:
Momentary push-button, (ON)-OFF
GROUND POWER AVAILABLE INDICATOR

GROUND POWER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ground Power Off*
Ground Power Center
Ground Power On*
*=Momentary
Hardware:
Honeywell 1TL1-7E
3-POS (ON)-OFF-(ON)
Center-Locking
Spring-loaded to Center
HYD ELEC1 LP INDICATOR

HYD ELEC2 LP INDICATOR

HYD ELEC1 OVHT INDICATOR

HYD ELEC2 OVHT INDICATOR

HYD ELEC1 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC1 Off
Hyd ELEC1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ELEC2 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ELEC2 Off
Hyd ELEC2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG1 LP INDICATOR

HYD ENG2 LP INDICATOR

HYD ENG1 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG1 Off
Hyd ENG1 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD ENG2 SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Hyd ENG2 Off
Hyd ENG2 On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
HYD STANDBY LOW PRESSURE INDICATOR

ProSim System: Hydraulic
ProSim Group: Indicator
ProSim Config Names:
Hyd standby low pressure
HYD STANDBY LOW QUANTITY INDICATOR

ProSim System: Hydraulic
ProSim Group: Indicator
ProSim Config Names:
Hyd standby low quantity
IGNITION SELECT SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Ignition select Both
Ignition select Left
Ignition select Right
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
IRS SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Normal
IRS Both on L
IRS Both on R
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
LAND ALT ENCODER

ProSim System: Pneumatic
ProSim Group: Encoder
ProSim Config Names:
Land alt in encoder
NOTE: other related inputs include:
Land alt in encoder pulse down Off (SWITCH)
Land alt in encoder pulse down On (SWITCH)
Land alt (NUMERICAL)
Land alt in (ANALOG)
Hardware:
Continuous rotary encoder switch
LAVATORY SMOKE INDICATOR

LIGHT MAIN RETRACT SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
For 2-Position Variation:
Light Main Retract L On
Light Main Retract L Off
Light Main Retract R On
Light Main Retract R Off
For 3-Position Variation:
Light Main Retract L 3 POS Retracted
Light Main Retract L 3 POS Extended
Light Main Retract L 3 POS On
Light Main Retract R 3 POS Retracted
Light Main Retract R 3 POS Extended
Light Main Retract R 3 POS On
Hardware:
2-POS ON-OFF, Honeywell 1TL133-2
3-POS ON-OFF-ON, Honeywell 1TL133-1
LIGHT MAIN FIXED SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Light Main Fixed L On
Light Main Fixed L Off
Light Main Fixed R On
Light Main Fixed R Off
Hardware:
Honeywell 1TL133-2
2-POS ON-OFF
LIGHTS ANTI COLLISION SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Anti collision Off
Lights Anti collision On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS LOGO SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Logo Off
Lights Logo On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS POSITION SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Position Off
Lights Position On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
NOTE: If the strobe light switch is a 3-position “Position Strobe & Steady”switch, this position light switch will not be there as the position lights are included as part of the 3-position switch.
LIGHTS RUNWAY TURNOFF SWITCHES

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Runway turnoff L On
Lights Runway turnoff L Off
Lights Runway turnoff R On
Lights Runway turnoff R Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS STROBE SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
2-POS:
Lights Strobe Off
Lights Strobe On
OR
3-POS:
Lights Strobe & Steady Strobe & Steady
Lights Strobe & Steady Off
Lights Strobe & Steady Steady
Hardware:
For 2-POS: Honeywell 1TL1-2 ON-OFF
For 3-POS: Honeywell 1TL1-1 ON-OFF-ON
LIGHTS TAXI SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Taxi On
Lights Taxi Off
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WHEEL WELL SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wheel well Off
Lights Wheel well On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
LIGHTS WING SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Lights Wing Off
Lights Wing On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
MACH TRIM FAIL INDICATOR

NO SMOKING SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
No Smoking Off
No Smoking Auto
No Smoking On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
OFF SCHED DESCENT INDICATOR

OUTFLOW VALVE POSITION GAUGE

OUTFLOW VALVE SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Outflow valve Off
Outflow valve Open
Outflow valve Close
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
OVHT TEST

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
OVHT test Off
OVHT test On
Hardware:
Momentary push button (ON)-OFF
PACK 1 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK 2 SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pack 1 Auto
Pack 1 High
Pack 1 Off
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PACK L INDICATOR

PACK R INDICATOR

PNEUMATIC ISOLATION SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pneumatic Isolation switch Open
Pneumatic Isolation switch Auto
Pneumatic Isolation switch Close
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locked in all 3 positions
PRESSURE DIFFERENTIAL GAUGE

PRESSURE GAUGE

ProSim System: Pneumatic
ProSim Group: Gauge
ProSim Config Names:
Pressure Left
Pressure Right
PRESSURIZATION ALTN INDICATOR

PRESSURIZATION AUTO FAIL INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization auto fail
PRESSURIZATION MANUAL INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Pressurization manual
PRESSURIZATION SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pressurization Auto
Pressurization Altn
Pressurization Man
Hardware:
8-POS rotary switch limited to 3 positions
PROBE HEAT A SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat A OFF
Probe heat A ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
PROBE HEAT B SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Probe heat B OFF
Probe heat B ON
Hardware:
Honeywell 1TL1-w
2-POS ON-OFF
RAM DOOR FULL OPEN L INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open L
Ram door full open L bright (GATE)
RAM DOOR FULL OPEN R INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Ram door full open R
Ram door full open R bright (GATE)
RECIRC FAN L SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan L Auto
Recirc Fan L Off
Recirc Fan L running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
RECIRC FAN R SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Recirc Fan R Auto
Recirc Fan R Off
Recirc Fan R running (GATE)
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
SEATBELT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Seatbelt Off
Seatbelt Auto
Seatbelt On
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
SOURCE OFF 1 INDICATOR

SOURCE OFF 2 INDICATOR

SPAR VALVE CLOSED L INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
SPAR Valve Closed L
SPAR Valve Closed L bright
This is a dual-brightness indicator
SPAR VALVE CLOSED R INDICATOR

ProSim System: Fuel
ProSim Group: Indicator
ProSim Config Names:
SPAR Valve Closed R
SPAR Valve Closed R bright
This is a dual-brightness indicator
SPEED TRIM FAIL INDICATOR

ProSim System: Flight Controls
ProSim Group: Indicator
ProSim Config Names:
Speed Trim Fail
SPOILER A SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Spoiler A Off
Spoiler A On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
SPOILER B SWITCH

ProSim System: Hydraulic
ProSim Group: Switch
ProSim Config Names:
Spoiler B Off
Spoiler B On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
STANDBY POWER OFF INDICATOR

STANDBY POWER SWITCH

ProSim System: Electric
ProSim Group: Switch
ProSim Config Names:
Standby power switch Off
Standby power switch Bat
Standby power switch Auto
Hardware:
Honeywell 1TL1-1
3-POS ON-OFF-ON
Defaults to Auto position when Guarded
START 1 SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 1 Off
Start 1 GRD
Start 1 CONT
Start 1 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
START 2 SWITCH

ProSim System: Penumatic
ProSim Group: Switch
ProSim Config Names:
Start 2 Off
Start 2 GRD
Start 2 CONT
Start 2 FLT
Hardware:
Cole P/N 6600-2266 Magnetic Switch
Push in to rotate to GRD position; magnetic hold on GRD position
TAT TEST SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
TAT test Off
TAT test Pushed
Hardware:
Momentary push button, (ON)-OFF
TEMP PROBE HEAT INDICATOR

TR UNIT INDICATOR

TRANSFER BUS OFF 1 INDICATOR

TRANSFER BUS OFF 2 INDICATOR

TRIM AIR SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trim air Off
Trim air On
Hardware:
Honeywell 1TL1-2D
2-POS ON-OFF
Locked in both positions
TRIP RESET SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Trip reset Off
Trip reset On
Hardware:
Momentary push button switch, (ON)-OFF
ProSim Config Names:
OVHT test Off
OVHT test On
VHF NAV SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
VHF NAV Normal
VHF NAV Both on 1
VHF NAV Both on 2
Hardware:
Honeywell 1TL1-1A
3-POS ON-OFF-ON
Locking in all three positions
WAI L VALVE OPEN INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI L Valve Open
WAI L Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WAI R VALVE OPEN INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
WAI R Valve Open
WAI R Valve Open bright (GATE)*
*This is a dual-brightness indicator. The bright state is a gate. Bright indicates the valve is in transit and dim indicates an full open state.
WINDOW HEAT FWD L OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L overheat
WINDOW HEAT SIDE L OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L overheat
WINDOW HEAT SIDE R OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R overheat
WINDOW HEAT FWD R OVERHEAT INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R overheat
WINDOW HEAT SIDE L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side L off*
Window heat Side L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD L INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD L off*
Window heat FWD L on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT FWD R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat FWD R off*
Window heat FWD R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE R INDICATOR

ProSim System: Heating
ProSim Group: Indicator
ProSim Config Names:
Window heat Side R off*
Window heat Side R on
*Not sure why this item is included. The ON item should be all that’s needed.
WINDOW HEAT SIDE L SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side L Off
Window heat Side L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT FWD L SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD L Off
Window heat FWD L On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT TEST SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat test OVHT*
Window heat test Center
Window heat test PWR TEST*
*=Momentary position (Spring-loaded to Center)
Hardware:
Honeywell 1TL1-7
3-POS (ON)-OFF-(ON)
WINDOW HEAT FWD R SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat FWD R Off
Window heat FWD R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WINDOW HEAT SIDE R SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Window heat Side R Off
Window heat Side R On
Hardware:
Honeywell 1TL1-2
2-POS ON-OFF
WING ANTI-ICE SWITCH

ProSim System: Heating
ProSim Group: Switch
ProSim Config Names:
Wing Anti-Ice Off
Wing Anti-Ice On
Wing Anti-Ice hold actuator (GATE)*
Wing Anti-Ice off actuator (GATE)*
*This is a magnetic locking switch. When the magnet is powered by activating the gate, the magnet holds the switch in the ON position.
Hardware:
Microswitch 25ET61-S, Magnetic 28V
2-POS ON-OFF
(alternate Honeywell 1TL1-2 non-magnetic)
WING-BODY OVERHEAT 1 INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 1
WING-BODY OVERHEAT 2 INDICATOR

ProSim System: Pneumatic
ProSim Group: Indicator
ProSim Config Names:
Wing-body overheat 2
WIPER LEFT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper left Park
Wiper left Int
Wiper left Low
Wiper left High
Hardware:
8-Position Rotary Switch (locked to 4 positions)
WIPER RIGHT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Wiper right Park
Wiper right Int
Wiper right Low
Wiper right High
Hardware:
8-Position Rotary Switch (locked to 4)
YAW DAMPER INDICATOR

YAW DAMPER SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Yaw damper Off
Yaw damper On*
*Magnetic Hold
Hardware:
2ET61-S 28V (alternate 1TL1-2)
2-POS (ON)-OFF (Magnetic hold ON)
ZONE TEMP CONT CAB INDICATOR

ZONE TEMP FWD CAB INDICATOR

ZONE TEMP AFT CAB INDICATOR

AFT Overhead (AFT OH)
AFT Overhead
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

ELT SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
ELT Arm
ELT On
Hardware:
2-POS ON-OFF
IRS DISP SEL SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Disp Sel TK/GS
IRS Disp Sel Test
IRS Disp Sel PPOS
IRS Disp Sel Wind
IRS Disp Sel HDG/STS
Hardware:
12-POS Rotary Switch, 30 degree detents
IRS SYS DSPL SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS SYS DSPL Left
IRS SYS DSPL Right
Hardware:
8-POS rotary switch, limited to 2 positions
LE DEVICES INDICATORS

ProSim System: Misc
ProSim Group: Indicator
ProSim Config Names:
Flaps extended 1
Flaps extended 2
Flaps extended 3
Flaps extended 4
Flaps transit 1
Flaps transit 2
Flaps transit 3
Flaps transit 4
Slats extended 1
Slats extended 2
Slats extended 3
Slats extended 4
Slats extended 5
Slats extended 6
Slats extended 7
Slats extended 8
Slats fullExtended 1
Slats fullExtended 2
Slats fullExtended 3
Slats fullExtended 4
Slats fullExtended 5
Slats fullExtended 6
Slats fullExtended 7
Slats fullExtended 8
Slats transit 1
Slats transit 2
Slats transit 3
Slats transit 4
Slats transit 5
Slats transit 6
Slats transit 7
Slats transit 8
IRS KEYPAD SWITCHES

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS Keypad 0 Off
IRS Keypad 0 Pushed
IRS Keypad 1 Off
IRS Keypad 1 Pushed
IRS Keypad 2 Off
IRS Keypad 2 Pushed
IRS Keypad 3 Off
IRS Keypad 3 Pushed
IRS Keypad 4 Off
IRS Keypad 4 Pushed
IRS Keypad 5 Off
IRS Keypad 5 Pushed
IRS Keypad 6 Off
IRS Keypad 6 Pushed
IRS Keypad 7 Off
IRS Keypad 7 Pushed
IRS Keypad 8 Off
IRS Keypad 8 Pushed
IRS Keypad 9 Off
IRS Keypad 9 Pushed
IRS Keypad CLR Off
IRS Keypad CLR Pushed
IRS Keypad ENT Off
IRS Keypad ENT Pushed
LE DEVICES TEST SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
LE Devices test Off
LE Devices test Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS LEFT ALIGN INDICATOR

IRS RIGHT ALIGN INDICATOR

IRS LEFT ON DC INDICATOR

IRS RIGHT ON DC INDICATOR

IRS LEFT FAULT INDICATOR

IRS RIGHT FAULT INDICATOR

IRS LEFT DC FAIL INDICATOR

IRS RIGHT DC FAIL INDICATOR

IRS LEFT SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS left Nav
IRS left Off
IRS left Align
IRS left Att
Hardware:
IRS RIGHT SWITCH

ProSim System: Navigation
ProSim Group: Switch
ProSim Config Names:
IRS right Nav
IRS right Off
IRS right Align
IRS right Att
Hardware:
PSEU INDICATOR

DOME LIGHT SWITCH

ProSim System: Lighting
ProSim Group: Switch
ProSim Config Names:
Dome light Dim
Dome light Off
Dome light Bright
Domelight bright (GATE)
Domelight dim (GATE)
Domelight master (GATE)
Hardware:
3-POS toggle switch, ON-OFF-ON
REVERSER LEFT INDICATOR

REVERSER RIGHT INDICATOR

ENGINE CONTROL LEFT INDICATOR

ENGINE CONTROL RIGHT INDICATOR

EEC LEFT

ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC left Off (SWITCH)
EEC left Pushed (SWITCH)
EEC left latch Off (SWITCH)
EEC left latch On (SWITCH)
EEC Altn left (INDICATOR)
EEC On left (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
EEC RIGHT

ProSim System: Engine
ProSim Group: Indicator & Switch
ProSim Config Names:
EEC right Off (SWITCH)
EEC right Pushed (SWITCH)
EEC right latch Off (SWITCH)
EEC right latch On (SWITCH)
EEC Altn right (INDICATOR)
EEC On right (INDICATOR)
Hardware:
This is a specialized switch/indicator combination. The indicators and switch are controlled via multiple inputs on the back-side of the switch housing. FlightDeck Solutions makes the one I have.
OXYGEN PRESSURE GAUGE

GEAR LEFT AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear left aft ovh
GEAR RIGHT AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear right aft ovh
GEAR NOSE AFT OVH INDICATOR

ProSim System: Landing Gear
ProSim Group: Indicator
ProSim Config Names:
Gear nose aft ovh
PASS OXY ON INDICATOR

PASS OXYGEN SWITCH

ProSim System: Pneumatic
ProSim Group: Switch
ProSim Config Names:
Pass oxygen Normal
Pass oxygen On
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the NORMAL position when guarded.
FLIGHT RECORDER SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Flight recorder Normal
Flight recorder Test
Hardware:
2-POS ON-OFF guarded toggle switch
Switch is in the Normal position when guard is closed.
FLIGHT RECORDER OFF INDICATOR

MACH AIRSPEED WARNING TEST NO1 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no1 Off
Mach Airspeed warning test no1 Pushed
Hardware:
Momentary push button, (ON)-OFF
MACH AIRSPEED WARNING TEST NO2 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Mach Airspeed warning test no2 Off
Mach Airspeed warning test no2 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 1 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 1 Off
Stall test 1 Pushed
Hardware:
Momentary push button, (ON)-OFF
STALL TEST 2 SWITCH

ProSim System: Misc
ProSim Group: Switch
ProSim Config Names:
Stall test 2 Off
Stall test 2 Pushed
Hardware:
Momentary push button, (ON)-OFF
IRS DISPLAY LCD

ProSim System: Navigation
ProSim Group: LCD
ProSim Config Names:
IRS Display
IRS Display left char state (NUMERICAL)
IRS Display left mode (NUMERICAL)
IRS Display left number (NUMERICAL)
IRS Display right char state (NUMERICAL)
IRS Display right mode (NUMERICAL)
IRS Display right number (NUMERICAL)
Center Pedestal
Center Pedestal
Click an item in the diagram at right to view its basic ProSim Config properties.
Click the More Info button that appears in this panel to visit the Combined Config reference table where you’ll find more detailed information on the item, if available.

ENGINE 1 OVERHEAT SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
Engine 1 overheat PTT Normal (SWITCH)
Engine 1 overheat PTT Pushed (SWITCH)
Engine 1 overheat (INDICATOR)
ENGINE 2 OVERHEAT SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
Engine 2 overheat PTT Normal (SWITCH)
Engine 2 overheat PTT Pushed (SWITCH)
Engine 2 overheat (INDICATOR)
OVHT DET LEFT SWITCH

ProSim System: Fire
ProSim Group: Switch
ProSim Config Names:
Ovht Det left Normal
Ovht Det left A
Ovht Det left B
Hardware:
3-POS, locked in all 3 positions, ON-OFF-ON
OVHT DET RIGHT SWITCH

ProSim System: Fire
ProSim Group: Switch
ProSim Config Names:
Ovht Det right Normal
Ovht Det right A
Ovht Det right B
Hardware:
3-POS, locked in all 3 positions, ON-OFF-ON
OVHT TEST SWITCH

ProSim System: Fire
ProSim Group: Switch
ProSim Config Names:
Ovht test Off
Ovht test Fault/Inop
Ovht test Ovht/Fire
Hardware:
3-POS momentary switch, (ON)-OFF-(ON)
FIRE HANDLE ENGINE 1 SWITCH/INDICATOR/GATE

ProSim System: Fire
ProSim Group: Switch/Indicator/Gate
ProSim Config Names:
Fire handle Engine 1 Off (SWITCH)
Fire handle Engine 1 Left (SWITCH)
Fire handle Engine 1 Right (SWITCH)
Fire handle pull Engine 1 Normal (SWITCH)
Fire handle pull Engine 1 Pull (SWITCH)
Engine 1 fire handle light (INDICATOR)
Fire handle unlock Engine 1 (GATE)
FIRE HANDLE ENGINE 2 SWITCH/INDICATOR/GATE

ProSim System: Fire
ProSim Group: Switch/Indicator
ProSim Config Names:
Fire handle Engine 2 Off (SWITCH)
Fire handle Engine 2 Left (SWITCH)
Fire handle Engine 2 Right (SWITCH)
Fire handle pull Engine 2 Normal (SWITCH)
Fire handle pull Engine 2 Pull (SWITCH)
Engine 2 fire handle light (INDICATOR)
Fire handle unlock Engine 2 (GATE)
FIRE HANDLE APU SWITCH/INDICATOR/GATE

ProSim System: Fire
ProSim Group: Switch/Indicator/Gate
ProSim Config Names:
Fire handle APU Off (SWITCH)
Fire handle APU Left (SWITCH)
Fire handle APU Right (SWITCH)
Fire handle pull APU Normal (SWITCH)
Fire handle pull APU Pull (SWITCH)
APU fire handle light (INDICATOR)
Fire handle unlock APU (GATE)
FIRE WHEEL WELL SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
Fire Wheel well PTT Normal (SWITCH)
Fire Wheel well PTT Pushed (SWITCH)
Fire Wheel well (INDICATOR)
FIRE FAULT SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
Fire Fault PTT Normal (SWITCH)
Fire Fault Pushed (SWITCH)
Fire Fault (INDICATOR)
FIRE APU DET INOP SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
Fire APU Det Inop PTT Normal (SWITCH)
Fire APU Det Inop Pushed (SWITCH)
Fire APU Det Inop (INDICATOR)
APU BOTTLE DISCHARGED SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
APU bottle discharged PTT Normal (SWITCH)
APU bottle discharged Pushed (SWITCH)
APU bottle discharged (INDICATOR)
L BOTTLE DISCHARGED SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
L bottle discharged PTT Normal (SWITCH)
L bottle discharged Pushed (SWITCH)
L bottle discharged (INDICATOR)
R BOTTLE DISCHARGED SWITCH/INDICATOR

ProSim System: Fire
ProSim Group: Switch / Indicator
ProSim Config Names:
R bottle discharged PTT Normal (SWITCH)
R bottle discharged Pushed (SWITCH)
R bottle discharged (INDICATOR)
BOTTLE SWITCHES/INDICATORS

ProSim System: Fire
ProSim Group: Switch/Indicator
ProSim Config Names:
APU bottle indicator PTT Normal (SWITCH)
APU bottle indicator PTT Pushed (SWITCH)
APU bottle indicator (INDICATOR)
L bottle indicator PTT Normal (SWITCH)
L bottle indicator PTT Pushed (SWITCH)
L bottle indicator (INDICATOR)
R bottle indicator PTT Normal (SWITCH)
R bottle indicator PTT Pushed (SWITCH)
R bottle indicator (INDICATOR)
Notes:
These three lights are called “squibs”. Each contains a momentary switch. The indicator lights either by pushing the squib, activating the Pushed switch state, or if the indicator is triggered.
FIRE EXT TEST SWITCH

ProSim System: Fire
ProSim Group: Switch
ProSim Config Names:
Fire Ext test Off
Fire Ext test 1
Fire Ext test 2
Hardware:
3-POS momentary switch, (ON)-OFF-(ON)
Mode Control Panel (MCP)
Mode Control Panel (MCP)
Coming Soon

Test
Test
Hi Ben, which columns are you talking about? If you mean the old ACE ones, I'm still using them until…